Announcements
- End of Semester LimitsTime limits will be in effect Saturday, November 30th – Tuesday, December 10th, inclusive.
- Required TrainingStudents are encouraged to complete training as early as possible. All returning students, faculty and staff must complete the Fabrication Lab Refresher.
- Reserving Machine TimeReserve Machine Time using the FabJob App. Use a TMP folder for short-term file storage for walk-up use and consultations.
Gund L31 (Project Room)
The following equipment is available for use in the Gund L31 Project Room:
Abrasive Cabinet
Due to risk of silica exposure , please make sure the side door is firmly closed before turning the unit on. Similarly, turn-off the unit before opening the side door and removing the workpiece.
Flammable Storage Cabinet
All flammable materials should be stored in a flammables cabinet to prevent the start and spread of fire.
Materials that are corrosive may need special containment, as might materials that may be reactive with other items stored in the cabinet. Review Section 7 of a material’s Safety Data Sheet (SDS) for this information. Contact a member of the Fabrication Lab if you have any questions.
All materials placed in this cabinet should be labeled clearly with owner’s name and contact information. The Lab is not responsible for loss of property. Cabinets will be cleaned-out at the end of the year, with materials being discarded as hazardous waste, regardless of labeling.
Spray Booth
One spray booth with turn-table and removable table to accommodate taller items is located in L31. A compressed air connection for air brush use is located within it.
Wait for the light to indicate it is safe to spray.
Please use brown craft paper beneath the items you spray, to keep the surface clean for the next user.
Observe the applicable Standard Operating Procedure (SOP) when using the booth. Use of most materials, including spray paint, should be done with the use of gloves and safety glasses, to protect yourself from exposure. Leave items to dry on the shelves beneath the spray area of the booth, so that propellants, solvents, and other air contaminants are captured by the exhaust and removed from the room.
Dispose of aerosol cans in the designated waste container.
Work Tables
Please keep in mind that tables are shared by many. Clean up after yourself, disposing of materials and returning tools and other supplies. Do not store work on tables as this prevents others from being able to use them.
Liquid Waste Disposal
Let things like cement and plaster harden and then dispose of in the regular trash, rather than as liquid waste.
Very few liquids can be disposed-of in the drain. Use the large white barrels for materials like water used to clean paint brushes, plaster, clay, and cement.
Contact a member of Fabrication Lab staff regarding disposal of any hazardous waste, like solvents, resins, and paints.
Sink
Hot and cold water. Use the sink to wash your hands or obtain water for casting. The drain is very sensitive and cannot handle solids like sand, clay, cement, or other materials.
Please use a rinse bucket that is disposed of in the liquid waste barrel for washing of any brushes, rollers, or tools used with plaster or cement, rather than washing these items in the sink.
Emergency Eyewash and Shower
Use to flush eyes or cleanse body in the case of accidental exposure. Follow emergency response guidelines in the material’s Safety Data Sheet.
Spill Containment Kit
Used to contain spills, especially those that may be hazardous. Contact FMO in case of any spill (617-49)5-5560, and notify Lab staff immediately.
Gund L33
While primarily acting as the Zünd Cutter room, Gund L33 is also the home to:
- Instron Load Tester (find link on the Tutorial Page)
- Roland CNC Mill
- Sewing Machines
Gund L40
While primarily acting as the Laser Cutting room, Gund L40 is also the home to the full-service 3D printers as well as the Vacuum Thermoformer.
Gund 518 (Spray Room)
The following equipment is available for use in the Gund 518 Spray Room:
Spray Booth
Four spray booths. Wait for the light to indicate it is safe to spray.
Please use brown craft paper beneath the items you spray, to keep the surface clean for the next user.
Observe the applicable Standard Operating Procedure (SOP) when using the booth. Use of most materials, including spray paint, should be done with the use of gloves and safety glasses, to protect yourself from exposure. Leave items to dry on the shelves beneath the spray area of the booth, so that propellants, solvents, and other air contaminants are captured by the exhaust and removed from the room.
Dispose of aerosol cans in the designated waste container.
Flammable Storage Cabinets
All flammable materials should be stored in a flammables cabinet to prevent the start and spread of fire.
Materials that are corrosive may need special containment, as might materials that may be reactive with other items stored in the cabinet. Review Section 7 of a material’s Safety Data Sheet (SDS) for this information. Contact a member of the Fabrication Lab if you have any questions.
All materials placed in this cabinet should be labeled clearly with owner’s name and contact information. The Lab is not responsible for loss of property. Cabinets will be cleaned-out at the end of the year, with materials being discarded as hazardous waste, regardless of labeling.
485 Broadway Room 224 (Workroom)
This is the space supporting fabrication for students with desk space in 485 Broadway. Here, you’ll find:
- Flammables Storage Cabinet (Note: there is no space to accommodate use of aerosol products at 485 Broadway. You must use them in a spray booth located in Gund Hall.)
- Self-Serve Dremel Printers
- Cricut
- Sink
- Workbenches
- Wire Racks for Temporary Storage
- Large Format Plotter
Announcements
- End of Semester LimitsTime limits will be in effect Saturday, November 30th – Tuesday, December 10th, inclusive.
- Required TrainingStudents are encouraged to complete training as early as possible. All returning students, faculty and staff must complete the Fabrication Lab Refresher.
- Reserving Machine TimeReserve Machine Time using the FabJob App. Use a TMP folder for short-term file storage for walk-up use and consultations.
Project Room Hours
While the Project Room is typically available whenever Gund Hall is open during the academic semesters, hours may be limited in the summer and between semesters.
Project Room Camera
View the Project Room Camera, Gund L31
View the Spray Room Camera, Gund 518
(Must be connected to the Harvard network by being on-campus, or connected via VPN to view remotely.)
The Fabrication Lab is intended for the use of the faculty, staff, and students enrolled in courses at the Graduate School of Design pursuing academic work. Please see our Policies page for more information.